mcr tecresa® » Tecbor® Boards » Tecbor® Boards – Curtain Walls

Tecbor® Boards - Curtain Walls

The DB SI in its section concerning external propagation, indicates that in order to limitate the risk of vertical propagation through the façade between two fire sectors, between a particularly high risk area and other higher zones
in the building, or towards a protected staircase or protected corridor, this façade shall be at least EI-60 in a belt with height of not less than 1 metre.

Catastrophes affecting high-rises have shown the importance of protecting and anchoring joints between both slabs and facades. Otherwise, existing holes between curtain walls and light facades can work as true chimneys in case of fire causing flames and smoke to get out of control propagating into higher areas in the building, and thus hampering an orderly evacuation procedure.

The manifold and various configurations of facades make it difficult to decide on the most appropriate protection. Therefore, do not hesitate to contact our Sales Department for assistance.

Muros cortina
TEST


Standard : UNE EN 1364-4
Laboratory : TECNALIA
Test Nº : 074490-001-2

SOLUTION


1. Tecbor®  30 mm boards.
2. Unbrella fasterners.
3. 40 x 40 x 2 mm angle.
4. M6 metal anchor.
5. 3,5 x 45 mm screw.
6. Tecbor Boards 30 mm cover.

Description of Assembly

Fix the 40 x 40 x 2 mm angle to the 30 mm Tecbor® Board by fixing umbrella fasteners spaced 500 mm apart.

Once the angles are fixed to the boards, attach to the slab using M6 metal anchor. Join the sections using 200 mm wide connector caps and fix with 3.5 x 45 mm screws.

Finally, apply Tecbor® Joint Paste or Tecbor® Bonding Compound to the board joints and screw heads

Tecbor Boards Catalogue

Product document

TEST


Standard : UNE EN 1364-4
Laboratory : CIDEMCO
Test Nº : 22100-2M1

SOLUTION


1. Tecbor® 20 mm boards.
2. 70 x 70 x 1 mm metal angle.
3. 3,5 x 45 mm Self-tapping screw.
4. 10 x 100 mm metal plug.
5. Slab.
6. Tecbor® boards 20 mm.

Description of Assembly

Attach the 70 x 70 x 1 mm angle lengthwise along the Tecbor® 20 mm Board using 3.5 x 45 mm self-tapping screws roughly every 250-300 mm. Attach the flush angle to the edge of the slab with a 10 x 100 mm plug approximately every 250-300 mm.

Next, fix a Tecbor® 20 mm cover, 200-250 mm wide, to the lower part of the slab using a 10 x 100 mm plug.

Tecbor® 20 mm joint covers (200-250 mm wide) are fixed to the lower joints of the curtain wall using 3.5 x 45 mm self-tapping screws.

Then apply Tecbor® Joint Paste to the board joints and screw heads.

Tecbor Boards Catalogue

Product document

TEST


Standard : UNE EN 1364-1
Laboratory : CIDEMCO
Test Nº : 18598-2M1

SOLUTION


1.  Tecbor® 20 mm boards.
2. 48 x 30 x 0,5 mm runner.
3. 3,5 x 35 mm self-tapping screw.
4. 10 x 60 mm metal plug.
5. Slab.
6. 46 x 36 x 0,6 mm stud.
7. 13 mm plasterboard.

Description of Assembly

Fix a 48x30x0.5 mm metal runner to the slab by using a 10×60 mm stud anchor. Place the 46x36x06 mm frames with a distance of 610 mm between the axes. Then fix the Tecbor® 20 mm boards to the structure by using 3,5×35 mm screws.

Apply Tecbor® Joint paste on all the joints between boards and on the heads of the screws.

Finally, fix a 13 mm plasterboard panel inside the solution by using 3,5×35 mm self-tapping screws.

Tecbor Boards Catalogue

Product document

TEST


Standard : UNE EN 1364-4
Laboratory : CIDEMCO
Test Nº : 12_02712

SOLUTION


1. Tecbor® 20 mm boards.
2. 48 x 30 x 0,5 mm runner.
3. 3,5 x 35 mm self tapping screw.
4. 3,5 x 45 mm self-tapping screw.
5. 10 x 60 mm metal plug.
6. Slab.
7. 46 x 36 x 0,6 mm stud.
8. 13 mm plasterboard.
9. 70 x 70 x 1 mm angle.

Description of Assembly

This is a curtain wall solution without assymetrical crossing slab. The upper side, is a partition without wool.

It consists in a 13 mm laminated plaster partition fixed on the inner side to a 46 mm metal stud by means of 3.5 x 35 mm dry partition hardware. On the opposite side, it has a 20 mm Tecbor® board fixed to the 46 metal stud by means of 3.5 x 35 mm dry partition hardware.

 

On the slab lower part, Tecbor® boards were installed with 70 x 70 x 1 mm angle and 3.5 x 45 mm screw.

Tecbor Boards Catalogue

Product document

TEST


Standard : UNE EN 1364-1
Laboratory : CIDEMCO
Test Nº : 13750 M1 & 14610 M1

SOLUTION


1. Tecbor® 10 mm boards.
2. 60 mm rock-wool (30+30) 100 Kg/m3.
3. Facade.
4. 50 mm rock-wool 145 Kg/m.
5. Facade anchor angle.
6. Slab.
7. 70 x 36 x 0,6 mm stud.
8. Closed facade (glass).
8. 3,5 x 25 mm self-drilling screws.

Description of Assembly

Place the 100 kg/m3 rock-wool between the facade studs. Once filled with rock-wool, attach the Tecbor® 10 mm Boards to the studs using 3.5 x 25 mm selfdrilling screws.

Close the junction between the slab and the module with a 10 mm-thick Tecbor® Board, fixed with 10×100 mm plugs every 250 mm along the underside of the slab.

Apply Tecbor® Joint Paste to the board joints, at the confluence of the sheet metal module and screw heads. The space between the slab and the module is filled with 145 kg/m3 dense rock-wool

Product document